TC-48-20 OEM - Te Technology TC-48-20 OEM Cool-only/Heat-only Thermoelectric Temperature Controller Simple Type:...
Request Quote
For Price
- Part Number:
- TC-48-20 OEM
- Model Number:
- TC-48-20 OEM
- Make:
- TE TECHNOLOGY
- Lead Time:
- Available
- Qty In Stock:
- Available
Te Technology TC-48-20 OEM Cool-only/Heat-only Thermoelectric Temperature Controller Simple Type: Temperature Controller
The TC-48-20 OEM is a basic version of the TC-48-20 controller that is a component for Original Equipment Manufacturers (OEM's) that want to integrate the controller in a system where the display, keypad, and box cover are not needed. The controller is shipped as the basic control circuit mounted on an aluminum panel. One standard thermistor (model MP-3193) and a software CD are included. The TC-48-20 OEM, like the standard TC-48-20, is a cool-only or heat-only thermoelectric temperature controller capable of controlling up to 50 volts and 20 amps. The controller uses one thermistor for temperature feedback, and a second thermistor can be attached for monitoring and alarm purposes. (One standard thermistors is included; additional thermistors can be purchased separately.) The controller is mounted to an aluminum plate, but is otherwise un-enclosed. All controller settings are communicated via RS232.
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- Analog proportional output signal for controlling programmable linear power supplies
- Best-case control stability ±0.1 °C (when controlling a cold plate)
- Computer programmable via RS 232 communication (An optional RS-232 cable, part number MP-3023, is required)
- Cool-only or heat-only control modes, menu selectable via software
- Optional secondary thermistor input for sensing alarm conditions
- RoHS compliant
- Single or dual power supply configurations allow a wide range of output voltages
- Two available alarm outputs, capable of sinking up to 1 A each, for triggering alarms based on the primary (control) sensor and/or secondary sensor
Specifications
- Derivative gain (D) adjustment: 0.00 to 10.00 cycles per minute
- Dual power supply configuration: Greater than or equal to 9 VDC, <50 VDC at 150 mA minimum for controller circuitry greater than or equal to 0 VDC, <50 VDC for TE device
- Integral gain (I) adjustment: 0.00 to 10.00 repeats per minute
- Maximum output current: 20 A combined TE device and alarm current
- Operating temperature range (non-condensing, total combined alarm and load : Minimum: 0 °C, Maximum: 48 °C in horizontal orientation, 20 A output; 55 °C vertical orientation, 20 A output; 53 °C horizontal orientation, 17 A output; 59 °C vertical orientation, 17 A output.
- Output: square wave, 337 Hz, pulse-width modulated, with soft start
- Proportional (P) bandwidth adjustment: 0.5 °C to 100.0 °C
- Single power supply configuration: Greater than or equal to 9 VDC, <50 VDC input, powering both controller and TE device
- Temperature control range: -20 °C to +100 °C using the MP-3193 thermistor supplied with the controller, or -20 °C to +85 °C using a thermistor equivalent to 10 k-ohm, curve "B" from YSI Temperature, Inc.
Applications
- None Available
Aliases